Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 308-310, 2022.
Article in Chinese | WPRIM | ID: wpr-935800

ABSTRACT

Objective: To investigate and monitor the occupational hazards in the Teaching and Research Laboratory (hereinafter referred to as the place) of a university, so as to provide basis for the occupational health work in the university. Methods: November 2014, 46 places in a university were selected by stratified random sampling, and the occupational health risk factors were investigated. Results: Indoor temperature, humidity, sulfur dioxide, nitrogen dioxide, carbon monoxide and carbon dioxide were detected in 21 sites, xylene and hydrofluoric acid were detected in 6 sites, and colony count was detected in 18 sites, the power frequency electric field intensity was measured in 23 places, and the x-ray radiation dose was measured in 4 places. Noise was measured at 21 sites, with 7 sites exceeding the standards accounting for 33.3% (7/21) ; 21 sites were detected for illumination and 10 sites for nonconformity accounting for 47.6% (10/21) ; 10 sites for Microwave Radiation and 3 sites exceeding the standards accounting for 30% (3/10) ; and 25 sites were detected for outdoor air volume and air velocity, the percentage of unqualified was 72% (18/25) in 18 sites, among which the wind velocity was statistically significant in teaching, research and experimental sites (P=0.010) . Conclusion: The occupational hazards in the teaching and research places of a university should be paid attention to, and the engineering protection and personal protection should be strengthened in the experiment.


Subject(s)
Humans , Air Pollution, Indoor/analysis , Humidity , Nitrogen Dioxide/analysis , Occupational Exposure , Occupational Health , Universities
2.
Chinese Journal of Preventive Medicine ; (12): 328-333, 2022.
Article in Chinese | WPRIM | ID: wpr-935288

ABSTRACT

Objective: To assess the association between short-term exposure level of nitrogen dioxide and the hospitalization risk of heart failure. Methods: Based on China-PEACE Retrospective Heart Failure Study, 117 364 hospitalized patients with heart failure were recruited from 92 hospitals in 62 cities throughout China between January 1, 2015 and December 31, 2015. The daily exposure level of nitrogen dioxide, temperature, and humidity in the same cities during the same period were also collected. We applied the generalized additive model and Bayesian hierarchical model to quantify the lagged effect and cumulative effect of short-term (0-3 days) exposure to ambient nitrogen dioxide on the hospitalization risk of heart failure. We further conducted stratified analyses by age, region, and season to identify any difference in the associations between short-term nitrogen dioxide exposure and heart failure among subgroups. Results: The mean age for participants in the analysis was (70.32±12.22) years. The median, minimum and maximum of daily nitrogen dioxide concentration in 62 cities from January 1, 2015 to December 31, 2015 was 26.4 μg/m3, 2.33 μg/m3 and 150.25 μg/m3, respectively. The exposure level of nitrogen dioxide at the same day was associated with the hospitalization risk of heart failure (OR=1.022, 95%CI: 1.012, 1.031). Significant effects were also observed in the moving average concentrations from lag 0-1 to lag 0-3 day (OR=1.020, 95%CI: 1.009, 1.030; OR=1.016, 95%CI: 1.004, 1.028; OR=1.013, 95%CI: 1.001, 1.026). Moreover, all of the associations between short-term exposure to nitrogen dioxide and the risk of heart failure hospitalization were statistically significant, with no significant difference in all subgroups stratified by age, region, and season. Conclusion: A higher level of short-term exposure to nitrogen dioxide could trigger more hospitalizations with heart failure.


Subject(s)
Aged , Aged, 80 and over , Humans , Middle Aged , Air Pollutants/analysis , Air Pollution/analysis , Bayes Theorem , China/epidemiology , Environmental Exposure/analysis , Heart Failure/epidemiology , Hospitalization , Nitrogen Dioxide/analysis , Particulate Matter/analysis , Retrospective Studies , Sulfur Dioxide/analysis
3.
Rev. ANACEM (Impresa) ; 14(2): 29-42, 2020. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1128982

ABSTRACT

En el sector de Quintero, desde los últimos 50 años han existido diversos hitos relacionados con la contaminación medioambiental. Iniciando con la instauración de la termoeléctrica "Ventanas" en 1950, Chilectra en 1958. En el año 1993 el ministerio de Agricultura de Chile declaró a Puchuncaví y Quintero como una "zona saturada de contaminación" por dióxido de azufre (SO2) y material particulado (MP10). En el año 2011, 135 trabajadores del complejo Ventana fallecieron producto del cáncer. Durante el 2014 hubo un derrame de petróleo en la Bahía de Quintero, 2015 un informe del Instituto de Fomento Pesquero (IFOP) arrojó cifras de arsénico que superan 23 veces la norma establecida por el Código Sanitario de Alimentos. Frente a dicho escenario, se hace evidente la necesidad de comprender cómo es la situación de los pobladores de dichas comunas. La presente investigación busca asociar los niveles de contaminación de las comuna de Quintero y el número de hospitalizaciones durante los años 2012 hasta el 2018.


In Quintero, since the last 50 years there have been various milestones related to environmental pollution. Starting with the installation of the "Ventanas" thermoelectric plant in 1950, Chilectra in 1958. In 1993, the Chilean Ministry of Agriculture declared Puchuncaví and Quintero as a "zone saturated with contamination" by sulfur dioxide (SO2) and particulate matter (MP10). In 2011, 135 workers at the Ventana complex died of cancer. During 2014 an oil spill emerged in Quintero Bay, 2015 a report by the Institute for Fisheries Development (IFOP) showed arsenic figures that exceed 23 times the norm established by the Sanitary Food Code. Faced with this scenario, the need to understand what the situation of the residents of said communes is like is evident. The present investigation seeks to associate the levels of contamination of the commun of Quintero and the number of hospitalizations during the years 2012 to 2018.


Subject(s)
Air Pollution , Environmental Exposure/statistics & numerical data , Environmental Pollutants/analysis , Hospitalization/statistics & numerical data , Ozone/analysis , Sulfur Dioxide/analysis , Chile , Regression Analysis , Risk Factors , Government Regulation , Methane/analysis , Nitrogen Dioxide/analysis
4.
Buenos Aires; GCBA. Gerencia Operativa de Epidemiología; 28 jun. 2019. a) f: 12 l:17 p. graf, tab.(GCBA. Gerencia Operativa de Epidemiología, 4, 149).
Monography in Spanish | UNISALUD, BINACIS, InstitutionalDB, LILACS | ID: biblio-1102790

ABSTRACT

informe realizado por los equipos de trabajo que pertenecen a Salud Ambiental, Agencia de Protección Ambiental y Gerencia Operativa de Epidemiología, del Gobierno de la Ciudad de Buenos Aires. En el presente informe se analizan una serie de indicadores que permiten observar los valores de contaminantes criterio: Material Particulado en suspensión menor a 10 micrones (PM 10), Monóxido de Carbono (CO) y Dióxido de Nitrógeno (NO2), registrados en las estaciones de Monitoreo de Calidad del Aire que posee la Ciudad (La Boca, Parque Centenario y Córdoba), las cuales registran las concentraciones de estos contaminantes en forma continua (durante 24 horas, los 365 días del año), mediante métodos homologados internacionalmente. El periodo registrado abarca los años 2010 hasta el año 2018 completo. (AU)


Subject(s)
Carbon Monoxide/analysis , Air Quality Control , Air Monitoring , Air Pollution/prevention & control , Air Pollution/statistics & numerical data , Particulate Matter/analysis , Nitrogen Dioxide/analysis , Environmental Health Surveillance
5.
Arq. bras. oftalmol ; 81(6): 481-489, Nov.-Dec. 2018. graf
Article in English | LILACS | ID: biblio-973849

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of air pollution on the ocular surface of patients with Sjögren's syndrome. Methods: We investigated the ocular surfaces of thirty patients with Sjögren's syndrome and thirty healthy volunteers (control group) living in the Metropolitan Area of Buenos Aires. We used nitrogen dioxide as an indicator of exposure to air pollution. An ocular symptoms questionnaire was answered by all subjects, who also underwent a complete ocular surface ophthalmic examination-including an Ocular Surface Disease Index questionnaire, biomicroscopy, tear breakup time, Schirmer 1 test, corneal and conjunctival vital staining with fluorescein and lissamine green, tear lysozyme concentration, and impression cytology. Results: In almost all ocular surface test findings, we found a positive and significant correlation between higher levels of exposure to air pollution and higher levels of ocular surface damage in both the control group and Sjögren's syndrome patients. In Sjögren's syndrome patients, the Ocular Surface Disease Index questionnaire, tear breakup time, vital staining and impression cytology showed a significant correlation between high levels of air pollution and ocular surface disease. In the control group, the Ocular Surface Disease Index questionnaire, tear breakup time, and impression cytology showed a significant correlation between high levels of air pollution and ocular surface disease. Conclusions: Here we demonstrated that in patients with dry eye syndrome associated with Sjögren, abnormalities of the ocular surface and eye irritation related to air pollution are more severe than those in the control group. We believe that measuring air quality should be not only an integral part of the evaluation of ocular surface disease but also a therapeutic consideration.


RESUMO Objetivo: Avaliar o efeito da poluição do ar na superfície ocular de pacientes com síndrome de Sjögren. Métodos: Foram investigadas as superfícies oculares de trinta pacientes com síndrome de Sjögren e trinta voluntários saudáveis (grupo controle) residentes na Região Metropolitana de Buenos Aires. Usamos o dióxido de nitrogênio como um indicador de exposição à poluição do ar. Um questionário de sintomas oculares foi respondido por todos os indivíduos, que também foram submetidos a um exame oftalmológico completo da superfície ocular - incluindo um questionário do Índice da Doença da Superfície Ocular, biomicroscopia, tempo de ruptura do filme lacrimal, teste de Schirmer 1, coloração da córnea e conjuntiva com fluoresceína e lissamina verde, concentração de lisozima lacrimal e citologia de impressão. Resultados: Em quase todos os achados do teste de superfície ocular, encontramos uma correlação positiva e significativa entre níveis mais altos de exposição à poluição do ar e níveis mais elevados de danos na superfície ocular tanto no grupo controle quanto nos pacientes com síndrome de Sjögren. Em pacientes com síndrome de Sjögren, o questionário do Índice da Doença da Superfície Ocular, tempo de ruptura do filme lacrimal, coloração vital e citologia de impressão mostraram uma correlação significativa entre altos níveis de poluição do ar e doença da superfície ocular. No grupo controle, o questionário do Índice de Doenças da Superfície Ocular, tempo de ruptura do filme lacrimal e citologia de impressão mostraram uma correlação significativa entre altos níveis de poluição do ar e doença da superfície ocular. Conclusões: Aqui demonstramos que, pacientes com síndrome de olho seco associada a Sjögren, as anormalidades da superfície ocular e a irritação ocular relacionadas à poluição do ar são mais graves do que aquelas no grupo controle. Acreditamos que a medição da qualidade do ar não deve ser apenas uma parte integral da avaliação da doença da superfície ocular, mas também uma consideração terapêutica.


Subject(s)
Humans , Adult , Middle Aged , Aged , Young Adult , Sjogren's Syndrome/chemically induced , Environmental Pollution/adverse effects , Nitrogen Dioxide/adverse effects , Argentina , Tears/chemistry , Severity of Illness Index , Dry Eye Syndromes/complications , Muramidase/chemistry , Sjogren's Syndrome/complications , Surveys and Questionnaires , Conjunctiva/chemistry , Cornea/chemistry , Nitrogen Dioxide/analysis
6.
Ciênc. Saúde Colet. (Impr.) ; 23(8): 2515-2522, Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-952737

ABSTRACT

Abstract The effects of exposure to air pollutants on human health are mainly reflected in respiratory diseases in children and elderly ones. An ecological time series study was carried out in Ribeirão Preto/SP data to examine the role of exposure to air pollutants and hospital admissions due to respiratory diseases in children under 10 years old. The study period was between January, 2011 and December, 2013. Particulate Matter (PM10), Nitrogen dioxide (NO2), and ozone (O3), temperature and air relative humidity, were analyzed to estimate the association with hospital admissions using a generalized linear model of Poisson's regression with lags of zero up to seven days after exposure to pollutants, adjusted by the day of the week, seasonality and effective temperature. The significance level adopted was p < 0.05. NO2, when analyzed in single pollutant model shown to be significant at lag 2 and 3 and when analyzed in the multi-pollutant model it shown to be significant at lags 2 up to 5, and lag 7 with relative risk between 1.05 and 1.09 per 10 μg/m3 increase in NO2 concentration, with an excess of 150 hospital admission and substantial increase in costs to Public Health System. The data enable the local health managers can take action to minimize these effects.


Resumo Os efeitos da exposição aos poluentes do ar sobre a saúde humana são principalmente refletidos nas doenças respiratórias, em crianças e idosos. Este estudo, do tipo ecológico de séries temporais, foi realizado em Ribeirão Preto/SP para examinar o papel da exposição a poluentes do ar e internações hospitalares por doenças respiratórias em crianças de até 10 anos de idade. O período de estudo foi entre 01.01.2011 e 31.12.2013. Material partículado (PM10), dióxido de nitrogênio (NO2) e ozônio (O3), temperatura e umidade relativa do ar foram analisadas para estimar a associação com internações hospitalares usando um modelo linear generalizado da regressão de Poisson com defasagens de zero até sete dias após a exposição, ajustado pelo dia da semana, sazonalidade e temperatura efetiva. Foi adotado alfa = 0,05. NO2 quando analisado no modelo unipoluente mostrou significância nos lags 2 e 3 e quando avaliado no modelo multi-poluente foi significativo nos lags 2 até 5, e lag 7, com risco relativo entre 1,05 e 1,09 por 10 μg/m3 de aumento em sua concentração, com excesso de 150 internações e aumento substancial dos custos para o sistema de saúde pública. Os dados permitem que o gestor local de saúde possa tomar medidas para minimizar estes efeitos.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Respiratory Tract Diseases/epidemiology , Environmental Exposure/adverse effects , Hospitalization/statistics & numerical data , Nitrogen Dioxide/analysis , Ozone/analysis , Ozone/adverse effects , Respiratory Tract Diseases/etiology , Temperature , Brazil , Linear Models , Poisson Distribution , Air Pollutants/analysis , Air Pollutants/adverse effects , Air Pollution/analysis , Air Pollution/adverse effects , Environmental Exposure/analysis , Particulate Matter , Nitrogen Dioxide/adverse effects
7.
Rev. peru. med. exp. salud publica ; 35(2): 190-197, abr.-jun. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-961888

ABSTRACT

RESUMEN Objetivos. Evaluar el cambio en los niveles ambientales de material particulado (2,5 y 10) (PM2,5 y PM10), dióxido de azufre (SO2) y dióxido de nitrógeno (NO2), posterior al reordenamiento vehicular en la avenida Abancay, entre 2013-2015 respecto a 2007-2009, comparando con otras dos avenidas sin implementación de un reordenamiento, la avenida Guillermo de La Fuente en el distrito de Comas y la avenida César Vallejo en el distrito de El Agustino. Materiales y métodos. Los datos ambientales fueron colectados por tres monitores de Dirección General de Salud Ambiental e Inocuidad Alimentaria del Ministerio de Salud como parte de la red de Vigilancia de la calidad del aire de la ciudad de Lima. El coeficiente beta de la regresión lineal permitió evaluar el cambio en la concentración de cada contaminante. Resultados. El reordenamiento de la Av. Abancay redujo 62% los niveles de PM2,5; 55% los niveles de PM10; 65% los niveles NO2; y 82% los de SO2. En las otras dos avenidas evaluadas no se observó disminución. Una reducción significativa de PM 2,5 (β: -53,11 μg/m3; IC 95%: -63,92 a -42,30), PM10 (β: -47,95 μg/m3; IC 95%: -62,61 a -33,37), NO2 (β:-41,71 μg/m3, IC 95%: -48,18 a -35,23) y SO2 (β: -28,59 μg/m3; IC 95%: -35,23 a -21,95) fueron observados en la Av. Abancay, respecto a las otras dos avenidas, posterior al reordenamiento vehicular. Conclusiones. El reordenamiento vehicular puede contribuir con la disminución continua de diversos contaminantes ambientales. La extensión de esta medida podría mejoraría la calidad de aire y estado de salud de la población residente en la ciudad de Lima.


Objective. To assess the change in environmental levels of PM2.5, PM10, SO2, and NO2, after the application of a traffic regulation plan in Abancay Avenue between the years 2013-2015 vs. to 2007-2009, and comparing it against two other avenues, in which no traffic regulation was implemented: Guillermo de La Fuente Avenue in the district of Comas and Cesar Vallejo Avenue in El Agustino. Materials and Methods. Environmental data were collected by three air monitors from the Ministry of Health's Environmental Health and Food Safety General Directorate (Dirección General de Salud Ambiental e Inocuidad Alimentaria) that are part of the Air Quality Surveillance network of the city of Lima. The beta coefficient of the linear regression allowed to assess change in the concentration of each pollutant. Results. The traffic regulation plan of Abancay Av. reduced the levels of PM2.5 by 62%; 55% for PM10 levels; 65% for the NO2 levels, and 82% for the SO2 levels. In the other two avenues assess, this reduction was not observed. A significant reduction in PM2.5 (β: -53.11 μg/m3; 95% CI: -63.92 to -42.30), PM10 (β: -47.99 μg/m3; 95% CI: -62.61 to -33.37), NO2 (β: -41.71 μg/m3; 95% CI: -48.18 to -35.23), and SO2 (β: -28.59 μg/m3; 95% CI: -35.23 to -21.95) was observed in Abancay Av., with respect to the other two avenues, after the traffic regulation plan was implemented. Conclusions. Traffic regulation can contribute to the continuous reduction of different air pollutants. The expansion of this measure could improve air quality and the health status of the residents of Lima.


Subject(s)
Sulfur Dioxide/analysis , Environmental Pollution/analysis , Particulate Matter/analysis , Traffic-Related Pollution/analysis , Nitrogen Dioxide/analysis , Peru , Time Factors , Cities
8.
Buenos Aires; GCBA. Gerencia Operativa de Epidemiología; 26 mayo 2017. a) f: 16 l:20 p. graf.(Boletín Epidemiológico Semanal: Ciudad Autónoma de Buenos Aires, 2, 40).
Monography in Spanish | UNISALUD, BINACIS, InstitutionalDB, LILACS | ID: biblio-1104283

ABSTRACT

El nitrógeno (N) es un gas sin olor, color ni sabor, que constituye el 78% del aire atmosférico, y en concentraciones dentro de límites normales, no es perjudicial para la salud. Su importancia como contaminante deriva de su capacidad de combinación con el oxígeno para formar diversos óxidos de nitrógeno. El dióxido de nitrógeno (NO2) es un gas más denso que el aire, de color marrón rojizo y olor acre. Es definido como un contaminante, criterio que altera de manera importante el aire urbano. El NO2 es un contaminante en sí mismo y un precursor en la generación de otras moléculas nocivas para la salud. se presentan una serie de gráficos que permiten observar los valores de NO2 en las estaciones de Monitoreo de Calidad del Aire que posee la Ciudad (La Boca, Parque Centenario y Córdoba), las cuales registran las concentraciones de este contaminante en forma continua (durante 24 horas, los 365 días del año) mediante métodos homologados internacionalmente. (AU)


Subject(s)
Air Quality Control , Air Monitoring , Environmental Quality , Air Pollutants/toxicity , Air Pollution/analysis , Air Pollution/prevention & control , Air Pollution/statistics & numerical data , Environmental Health Surveillance , Nitrogen Dioxide/analysis , Nitrogen Dioxide/adverse effects , Nitrogen Dioxide/toxicity
9.
Rev. saúde pública ; 51: 13, 2017. tab, graf
Article in English | LILACS | ID: biblio-845896

ABSTRACT

ABSTRACT OBJECTIVE To evaluate the effects of acute exposure to air pollutants (NO2 and PM10) on hospitalization of adults and older people with cardiovascular diseases in Western São Paulo. METHODS Daily cardiovascular-related hospitalization data (CID10 – I00 to I99) were acquired by the Department of Informatics of the Brazilian Unified Health System (DATASUS) from January 2009 to December 2012. Daily levels of NO2 and PM10 and weather data were obtained from Companhia Ambiental do Estado de São Paulo (CETESB – São Paulo State Environmental Agency). To estimate the effects of air pollutants exposure on hospital admissions, generalized linear Poisson regression models were used. RESULTS During the study period, 6,363 hospitalizations were analysed. On the day of NO2 exposure, an increase of 1.12% (95%CI 0.05–2.20) was observed in the interquartile range along with an increase in hospital admissions. For PM10, a pattern of similar effect was observed; however, results were not statistically significant. CONCLUSIONS Even though with values within established limits, NO2 is an important short-term risk factor for cardiovascular morbidity.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Air Pollutants/toxicity , Air Pollution/adverse effects , Cardiovascular Diseases/etiology , Hospitalization/statistics & numerical data , Incineration , Inhalation Exposure/adverse effects , Saccharum , Brazil , Cardiovascular System/drug effects , Nitrogen Dioxide/analysis , Nitrogen Dioxide/toxicity , Particulate Matter/analysis , Particulate Matter/toxicity , Risk Assessment , Risk Factors , Seasons , Time Factors
10.
Rev. saúde pública ; 47(6): 1059-1068, dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-702729

ABSTRACT

OBJETIVO : Analisar a qualidade do ar em escolas de educação básica e suas condições estruturais e funcionais. MÉTODOS : Foi avaliada a qualidade do ar de 51 escolas (81 salas de aula) de educação básica da cidade de Coimbra, Portugal, tanto na parte interior das salas como na exterior, durante as quatro estações do ano, de 2010 a 2011. Foram avaliadas a temperatura (Tº), umidade relativa (Hr), concentrações de monóxido de carbono (CO), dióxido de carbono (CO 2 ), ozona (O 3 ), dióxido de nitrogênio (NO 2 ), dióxido de enxofre (SO 2 ), compostos orgânicos voláteis (COV), formaldeído e material particulado (PM 10 ), de novembro de 2010 a fevereiro de 2011 (outono/inverno) e de março de 2011 a junho de 2011 (primavera/verão). Procedeu-se ao preenchimento de uma grelha de caracterização das condições estruturais e funcionais das escolas. Aplicaram-se os testes estatísticos t- Student para amostras emparelhadas e o teste t de Wilcoxon. RESULTADOS : Em 47 escolas, as concentrações médias de CO 2 encontravam-se acima da concentração máxima de referência (984 ppm) mencionada na legislação portuguesa. Os valores máximos de concentração encontrados no interior das salas foram críticos, principalmente no outono/inverno (5.320 ppm). As concentrações médias de COV e de PM 10 no interior ultrapassaram a concentração máxima de referência legislada em algumas escolas. Não foram detetados valores relevantes (risco) de CO, formaldeído, NO 2 , SO 2 e O 3 . CONCLUSÕES : Houve maior concentração de poluentes no interior das salas, comparativamente com o exterior. A inadequada ventilação está associada à elevada concentração de CO 2 nas salas de aula. .


OBJETIVO : Analizar la calidad del aire en escuelas de educación básica y sus condiciones estructurales y funcionales. MÉTODOS : Se evaluó la calidad del aire de 51 escuelas (81 salas de aula) de educación básica de la ciudad de Coimbra, Portugal, tanto en el interior de las salas como en el exterior, durante las cuatro estaciones del año, de 2010 a 2011. Se evaluaron la temperatura (T°), humedad relativa (Hr), concentraciones de monóxido de carbono (CO), dióxido de carbono (CO2), ozono (O3), dióxido de nitrógeno (NO2), dióxido de azufre (SO2), compuestos orgánicos volátiles (COV), formaldehido (HCHO) y material particulado (PM10), de noviembre de 2010 a febrero de 2011 (otoño/invierno) y de marzo de 2011 a junio de 2011 (primavera/verano). Se procedió a llenar una tabla de caracterización de las condiciones estructurales y funcionales de las escuelas. Se aplicaron las pruebas estadísticas t-Student para muestras pareadas y la prueba t de Wilcoxon. RESULTADOS : En 47 escuelas, las concentraciones promedio de CO2 estaban por encima de la concentración máxima de referencia (984 ppm) mencionada en la legislación portuguesa. Los valores máximos de concentración encontrados en el interior de las salas fueron críticos, principalmente en el otoño/invierno (5.320 ppm). Las concentraciones promedio de COV y de PM10 en el interior sobrepasaron la concentración máxima de referencia legislada en algunas escuelas. No fueron detectados valores relevantes (riesgo) de CO, HCHO, NO2, SO2 y O3. CONCLUSIONES : Hubo mayor concentración de contaminantes en el interior de las salas, en comparación con el exterior. La inadecuada ventilación está asociada con la elevada concentración de CO2 en las salas de aula. .


OBJECTIVE : To analyze the air quality in elementary schools and their structural and functional conditions. METHODS : Air quality in 51 elementary schools (81 classrooms) in the city of Coimbra, Portugal, both inside and outside of the rooms was evaluated during the four seasons, from 2010 to 2011. Temperature (T°), relative humidity (Hr), concentrations of carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), compounds were evaluated, as were volatile organics (VOC), formaldehyde and particulate matter (PM10), from November 2010 to February 2011 (autumn/winter) and March 2011 to June 2011 (spring/summer). A grid characterizing the structural and functional conditions of the schools was created. The statistical Student t test for paired samples and the Wilcoxon t test were applied. RESULTS : In 47 schools, the average CO2concentrations were above the maximum reference concentration (984 ppm) mentioned in Portuguese legislation. The maximum concentration values found inside the rooms were critical, especially in the fall/winter (5,320 ppm). In some schools the average concentrations of VOC and PM10within the maximum concentration exceeded the reference legislated. The values (risk) of CO, formaldehyde, NO2, SO2and O3detected were not relevant. CONCLUSIONS : There was a higher concentration of pollutants inside the rooms compared with outside. Inadequate ventilation is associated with high CO2concentration in the classroom. .


Subject(s)
Air Pollutants/analysis , Air Pollution, Indoor/analysis , Schools/statistics & numerical data , Air Pollutants/chemistry , Air Pollution, Indoor/statistics & numerical data , Carbon Dioxide/analysis , Carbon Monoxide/analysis , Nitrogen Dioxide/analysis , Portugal , Risk Assessment , Seasons
11.
Rev. chil. enferm. respir ; 29(2): 81-88, abr. 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-687141

ABSTRACT

In the last 30 years, the Metropolitan Zone of Guadalajara (ZMG) has experienced a quick urban and industrial growth, situation which results in high rates of pollution and poor air quality harmful to the health of the population. The main purpose of this work was to analyze the SO2 and NO2 in the air, as well as ions H+, SO 4-2 and NO3- during the wet season of 2005. Results of the network of monitoring stations showed significant acidity in north-northwest and southeast of the study area. The maximum concentrations of SO 4-2 occurred in southeast and south, while the maximum NO3- was found in the south. Maximum levels of SO2 and NO2 occurred in the dry season, but it decreased in wet season. The higher frequency about acidity produced by NO2 is caused by mobile sources as the primary indicator.


En los últimos 30 años, la Zona Metropolitana de Guadalajara (ZMG) ha experimentado un acelerado crecimiento urbano-industrial, realidad traducida en contaminantes nocivos para la salud de la población. El objetivo de este trabajo fue analizar la concentración de dióxido de azufre (SO 2) y de nitrógeno (NO2) en el aire, así como, los iones hidrógeno (H+), sulfatos (SO 4-2) y nitratos (NO3-) durante la temporada de lluvias del año 2005. Mediante una red de estaciones de monitoreo, se obtuvieron resultados que revelaron acidez significativa al norte-noroeste y sureste. Las concentraciones máximas de SO4-2 ocurrieron al sureste y sur, mientras que, las de NO3- se localizaron al sur. Los niveles máximos de SO2 y NO2 sucedieron en el período seco, disminuyendo en el húmedo. Se observó mayor frecuencia de acidez por NO2 siendo el indicador principal las fuentes móviles.


Subject(s)
Air Pollution , Sulfur Dioxide/analysis , Nitrogen Dioxide/analysis , Acid Rain/analysis , Hydrogen-Ion Concentration , Mexico , Public Health , Urban Area
12.
Rev. colomb. biotecnol ; 11(1): 114-124, jul. 2009. graf
Article in Spanish | LILACS | ID: lil-590637

ABSTRACT

Los procesos avanzados para la remoción de nitrógeno están íntimamente relacionados con los metabolismos de las comunidades microbianas que intervienen en las transformaciones del mismo. Para el diseño, la optimización o el mejoramiento de los sistemas de tratamiento de aguas residuales domésticas, el ingeniero y el microbiólogo en forma conjunta, han logrado configurar reactores terciarios adecuados para el desenvolvimiento de estas comunidades, obteniendo altas eficiencias de remoción de los nutrientes. Este artículo presenta una revisión sobre la actividad bacteriana y su aplicación en los sistemas de tratamiento, inicia conceptualizando la influencia de los microorganismos y de la actividad humana en el ciclo global del nitrógeno, para después hacer un análisis de los procesos particulares en los cuales los microorganismos intervienen. Se clasifican e incluyen nuevas evidencias de metabolismos relacionados, y se describen como ejemplos algunos de los procesos de tratamiento terciario para aguas residuales desarrollados con éxito en las últimas décadas.


Advanced processes for nitrogen removal are intimately related to the microbial community metabolisms that take part in the transformations. For the design, optimization or improvement of domestic waste water treatment systems, engineers and microbiologists working together, have managed to implemented suitable tertiary reactors for the development of these communities, improving the efficiency of nutrient removal. This article presents a revision of the bacterial activity and its application in treatment systems. The article begins by giving an explanation about the influence of microorganism and human activity on the global nitrogen cycle. Then, it analyzes the particular processes in which the microorganisms take part. New evidence of related metabolisms are classified and included. Some of the processes of wastewater tertiary treatment, successfully developed over the last decades, are described as examples.


Subject(s)
Nitrogen Dioxide/analysis , Nitrogen Dioxide/metabolism , Nitrogen Dioxide/chemistry , Nitrogen Dioxide/chemical synthesis , Nitrogen/isolation & purification , Nitrogen/pharmacology , Nitrogen/metabolism , Nitrogen/chemistry
13.
J Environ Biol ; 2007 Apr; 28(2): 257-63
Article in English | IMSEAR | ID: sea-113137

ABSTRACT

Higher concentration of SO2 and particulate matters was reported in surrounding areas of coal-fired industries which influences the distribution pattern of plants. Sensitive plant species are abolished from such areas, however, only pollution tolerant species survive under stress conditions. The present study was designed to investigate the vegetation composition around coal-fired industries i.e. brick industries. To categorise plants as sensitive or resistant air pollution tolerance index (APTI) value was calculated. Out of 99 plants studied, Ricinus communis with APTI 81.10 was found to be the most resistant wild plant showing uniform distribution at all the polluted sites. On the other hand, Lepidium sativum with APTI 5.27 was recorded as the most sensitive plant and found to be present only at the less polluted sites.


Subject(s)
Adaptation, Physiological , Air Pollutants/analysis , Air Pollution/analysis , Ascorbic Acid/metabolism , Chlorophyll/metabolism , Coal , Construction Materials , Environmental Monitoring , Hydrogen-Ion Concentration , India , Industry , Nitrogen Dioxide/analysis , Particulate Matter/analysis , Plant Leaves/metabolism , Plants/metabolism , Sulfur Dioxide/analysis , Water/metabolism
14.
Noise Health ; 2004 Apr-Jun; 6(23): 21-8
Article in English | IMSEAR | ID: sea-122069

ABSTRACT

A correlation of respiratory diseases to traffic related air pollution and noise was observed in an interview study. Since in that study the exposure was subjectively assessed, in the present field study nitrogen dioxide as indicator for vehicle exhausts and the mean night-time noise level were measured outside the children's windows in representative locations. Based on these measurements each child was placed in one of the following categories: low, medium or high traffic immission (ambient emissions). The physician contacts due to bronchitis of 68 children were assessed retrospectively from the files of the participating paediatricians. Saliva samples were collected from all children and the cortisol concentration was estimated. Children under high noise exposure (L(night, 8h) = 54-70dB(A)) had in comparison to all other children significantly increased morning saliva cortisol concentrations, indicating an activation of the hypothalamus-pituitary-adrenal (HPA) axis. Analysing a subgroup of children without high noise exposure showed, that children with frequent physician contacts due to bronchitis did not have increased morning saliva cortisol. However, multiple regression analysis with stepwise exclusion of variables showed that bronchitis was correlated more closely to morning salvia cortisol than to traffic immissions. On the other hand, the rate of physician contacts due to bronchitis increased in a dose dependent manner and significantly with increasing traffic immissions. From these results it can be concluded that high exposure to traffic noise, especially at nighttime, activates the HPA axis and this leads in the long term to an aggravation of bronchitis in children. This seems to be more important than the effect of exhaust fumes on bronchitis symptoms. The results of the present study should be subjected to further investigation using specially designed studies.


Subject(s)
Bronchitis/etiology , Child , Child, Preschool , Germany , Humans , Hydrocortisone/analysis , Nitrogen Dioxide/analysis , Noise/adverse effects , Retrospective Studies , Saliva/metabolism , Vehicle Emissions/adverse effects
15.
Article in English | IMSEAR | ID: sea-114190

ABSTRACT

The concentration of suspended particulate matter (SPM), nitrogen dioxide (NO,) and sulphur dioxide (SO2) were measured at 13 important traffic intersections in Pune city. In order to study the contribution of these pollutants from motor vehicles, attention was focused on the roadside, street-level concentration. The statistical analysis of the sampling results indicates that there is not only high correlation between SPM and NO2 but the levels of these pollutants are above the National Ambient Air Quality Standards (NAAQS) laid down by the Central Pollution Control Board (CPCB), India. The SO, concentrations are found to be well below the NAAQS.


Subject(s)
Air Pollutants/analysis , Environmental Monitoring , India , Nitrogen Dioxide/analysis , Particle Size , Sulfur Dioxide/analysis , Vehicle Emissions/analysis
17.
Rev. cuba. hig. epidemiol ; 33(1/2): 56-63, ene.-dic. 1995. ilus, tab
Article in Spanish | LILACS | ID: lil-168842

ABSTRACT

Se muestra la influencia de diversos factores meteorologicos sobre el NO2 troposferico en 2 localidades de la Ciudad de La Habana, analizando segun los tipos de situaciones sinopticas que han afectado esta ciudad durante el periodo de 1986 a 1991


Subject(s)
Atmosphere , Nitrogen Dioxide/analysis , Meteorological Concepts
18.
Arch. argent. alerg. inmunol. clín ; 24(3): 116-25, ago. 1993. ilus
Article in Spanish | LILACS | ID: lil-125902

ABSTRACT

Se siguió durante un año, el comportamiento clínico diario del 100% de los asmáticos adultos pertenecientes al Municipio Plaza de la Revolución en Ciudad de La Habana. Correlacionamos las eventualidades diarias de su estado de salud con los siguientes factores climatológicos: temperatura, humedad relativa, velocidad del viento, presión atmosférica y lluvia, obtenidos todos en el Departamento de Climatología del Instituto de Meteorología de la Academia de Ciencias de Cuba. Para medir la contaminación de la zona se instaló una estación de muestreo tomándose las muestras diariamente para dosificar Dióxido de Azufre, Dióxido de Nitrógeno y Hollín; estas muestras se procesaron en el Instituto Nacional de Higiene y Epidemiología. El análisis estadístico que se utilizó fue: entrecruzamiento de variables, regresión múltiple, método paso a paso del paquete estadístico SPSS/PC-PLUS. Se concluye que las crisis asmáticas se correlacionaron de forma inversa con: temperatura, humedad relativa y lluvia; y directa con: velocidad del viento y presión atmosférica. No se constató correlación significativa con los contaminantes primarios de la atmósfera


Subject(s)
Humans , Adult , Asthma/epidemiology , Atmospheric Pressure , Air Pollution/analysis , Air Pollution/statistics & numerical data , Sulfur Dioxide/isolation & purification , Nitrogen Dioxide/analysis , Humidity/adverse effects , Rain , Temperature , Wind
SELECTION OF CITATIONS
SEARCH DETAIL